[Gen-art] Re: Genart last call review of draft-ietf-teas-gmpls-controller-inter-work-14

"Linyi (Yi)" <yi.lin@huawei.com> Tue, 16 July 2024 15:13 UTC

Return-Path: <yi.lin@huawei.com>
X-Original-To: gen-art@ietfa.amsl.com
Delivered-To: gen-art@ietfa.amsl.com
Received: from localhost (localhost [127.0.0.1]) by ietfa.amsl.com (Postfix) with ESMTP id 8CF3BC14F616; Tue, 16 Jul 2024 08:13:19 -0700 (PDT)
X-Virus-Scanned: amavisd-new at amsl.com
X-Spam-Flag: NO
X-Spam-Score: -4.093
X-Spam-Level:
X-Spam-Status: No, score=-4.093 tagged_above=-999 required=5 tests=[BAYES_00=-1.9, HTML_MESSAGE=0.001, HTML_TAG_BALANCE_BODY=0.1, RCVD_IN_DNSWL_MED=-2.3, RCVD_IN_MSPIKE_H3=0.001, RCVD_IN_MSPIKE_WL=0.001, RCVD_IN_ZEN_BLOCKED_OPENDNS=0.001, SPF_HELO_NONE=0.001, SPF_PASS=-0.001, T_HTML_ATTACH=0.01, T_SCC_BODY_TEXT_LINE=-0.01, URIBL_BLOCKED=0.001, URIBL_DBL_BLOCKED_OPENDNS=0.001, URIBL_ZEN_BLOCKED_OPENDNS=0.001] autolearn=ham autolearn_force=no
Received: from mail.ietf.org ([50.223.129.194]) by localhost (ietfa.amsl.com [127.0.0.1]) (amavisd-new, port 10024) with ESMTP id 6GKzCffjKEXA; Tue, 16 Jul 2024 08:13:15 -0700 (PDT)
Received: from frasgout.his.huawei.com (frasgout.his.huawei.com [185.176.79.56]) (using TLSv1.2 with cipher AECDH-AES256-SHA (256/256 bits)) (No client certificate requested) by ietfa.amsl.com (Postfix) with ESMTPS id 61569C14F5F3; Tue, 16 Jul 2024 08:13:13 -0700 (PDT)
Received: from mail.maildlp.com (unknown [172.18.186.31]) by frasgout.his.huawei.com (SkyGuard) with ESMTP id 4WNjFD75DKz6K98S; Tue, 16 Jul 2024 23:10:56 +0800 (CST)
Received: from lhrpeml500001.china.huawei.com (unknown [7.191.163.213]) by mail.maildlp.com (Postfix) with ESMTPS id C418C1400CF; Tue, 16 Jul 2024 23:13:09 +0800 (CST)
Received: from dggpemf100009.china.huawei.com (7.185.36.128) by lhrpeml500001.china.huawei.com (7.191.163.213) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.1.2507.39; Tue, 16 Jul 2024 16:13:07 +0100
Received: from dggpemf200009.china.huawei.com (7.185.36.246) by dggpemf100009.china.huawei.com (7.185.36.128) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.2.1544.11; Tue, 16 Jul 2024 23:13:05 +0800
Received: from dggpemf200009.china.huawei.com ([7.185.36.246]) by dggpemf200009.china.huawei.com ([7.185.36.246]) with mapi id 15.02.1544.011; Tue, 16 Jul 2024 23:13:05 +0800
From: "Linyi (Yi)" <yi.lin@huawei.com>
To: Thomas Fossati <thomas.fossati@linaro.org>, "gen-art@ietf.org" <gen-art@ietf.org>
Thread-Topic: Genart last call review of draft-ietf-teas-gmpls-controller-inter-work-14
Thread-Index: AdrQDOBZOlG8al5xRsCqiBqbdQ7yHA==
Message-ID: <6415a3a0f4194c769878fdbbf82a2406@huawei.com>
Accept-Language: zh-CN, en-US
Content-Language: zh-CN
X-MS-Has-Attach: yes
X-MS-TNEF-Correlator:
x-originating-ip: [10.203.45.96]
Content-Type: multipart/mixed; boundary="_005_6415a3a0f4194c769878fdbbf82a2406huaweicom_"
MIME-Version: 1.0
X-MailFrom: yi.lin@huawei.com
X-Mailman-Rule-Hits: max-size
X-Mailman-Rule-Misses: dmarc-mitigation; no-senders; approved; emergency; loop; banned-address; member-moderation; header-match-gen-art.ietf.org-0; header-match-gen-art.ietf.org-1; header-match-gen-art.ietf.org-2; nonmember-moderation; administrivia; implicit-dest; max-recipients; news-moderation; no-subject; digests; suspicious-header
Message-ID-Hash: ZN6S32M2O7ZNZJ5EHWSIXBRFIXEXAQYI
X-Message-ID-Hash: ZN6S32M2O7ZNZJ5EHWSIXBRFIXEXAQYI
X-Mailman-Approved-At: Thu, 18 Jul 2024 06:07:22 -0700
CC: "draft-ietf-teas-gmpls-controller-inter-work.all@ietf.org" <draft-ietf-teas-gmpls-controller-inter-work.all@ietf.org>, "last-call@ietf.org" <last-call@ietf.org>, "teas@ietf.org" <teas@ietf.org>, James Guichard <james.n.guichard@futurewei.com>
X-Mailman-Version: 3.3.9rc4
Precedence: list
Subject: [Gen-art] Re: Genart last call review of draft-ietf-teas-gmpls-controller-inter-work-14
List-Id: "GEN-ART: General Area Review Team" <gen-art.ietf.org>
Archived-At: <https://mailarchive.ietf.org/arch/msg/gen-art/oi_NRcg0NRGqhGUhD_34DRIRbSw>
List-Archive: <https://mailarchive.ietf.org/arch/browse/gen-art>
List-Help: <mailto:gen-art-request@ietf.org?subject=help>
List-Owner: <mailto:gen-art-owner@ietf.org>
List-Post: <mailto:gen-art@ietf.org>
List-Subscribe: <mailto:gen-art-join@ietf.org>
List-Unsubscribe: <mailto:gen-art-leave@ietf.org>
Date: Tue, 16 Jul 2024 15:13:19 -0000
X-Original-Date: Tue, 16 Jul 2024 15:13:05 +0000

Dear Thomas,



Many thanks for the review and comments. Please see my replies in line with [Author], and check whether all your comments are resolved.



Please see the attached new version (-15) of this draft (will be submitted once the I-D submission tool is reopened), as well as the diff between -14 and -15.



Please also note that there are some more modifications according to the comments from other reviewers.



Thank you.



B.R.

Yi LIN



HUAWEI France

Marco Polo A2, 790 Avenue Maurice Donat, 06250 Mougins France

http://www.huawei.com

---------------------------------------------------------------------------------------------

This e-mail and its attachments contain confidential information from HUAWEI, which

is intended only for the person or entity whose address is listed above. Any use of the

information contained herein in any way (including, but not limited to, total or partial

disclosure, reproduction, or dissemination) by persons other than the intended

recipient(s) is prohibited. If you receive this e-mail in error, please notify the sender

by phone or email immediately and delete it!



-----邮件原件-----

发件人: Thomas Fossati via Datatracker <noreply@ietf.org>

发送时间: 2024年6月23日 19:31

收件人: gen-art@ietf.org

抄送: draft-ietf-teas-gmpls-controller-inter-work.all@ietf.org; last-call@ietf.org; teas@ietf.org

主题: Genart last call review of draft-ietf-teas-gmpls-controller-inter-work-14



Reviewer: Thomas Fossati

Review result: Ready with Issues



I am the assigned Gen-ART reviewer for this draft. The General Area Review Team (Gen-ART) reviews all IETF documents being processed by the IESG for the IETF Chair.  Please treat these comments just like any other last call comments.



For more information, please see the FAQ at



<https://wiki.ietf.org/en/group/gen/GenArtFAQ>.



Document: draft-ietf-teas-gmpls-controller-inter-work-??

Reviewer: Thomas Fossati

Review Date: 2024-06-23

IETF LC End Date: 2024-06-26

IESG Telechat date: Not scheduled for a telechat



Summary:



The document is clear.



Major issues:



None



Minor issues:



My complete lack of expertise in the field prevents me from making concrete suggestions (and I apologise for that), but I've found the "Manageability Considerations" section to be a bit lacking in terms of content and exposition

- at least compared to the rest of the document.  The "Security Considerations"

are also a bit dry.  In particular, collecting all the references that apply in one place would be handy.

[Author] We modified these two sections and added some related references. Please see the attached document. Thank you.





Nits/editorial comments:



A few editorial suggestions follow.

[Author] Thanks for the nits/editorial comments. All are accepted in the new version of this draft.

Please note that, as suggested by Stewart Bryant, another reviewer from rtg-dir, a new Section 2 about Abbreviations was added, therefore all the sections after Section 2 are moved ahead of 1.





Abstract, paragraph 5:

OLD:



    On the other hand, with the development of software-defined

    transport networking technology, a set of NEs can be controlled via

    centralized controller hierarchies to address the issues from multi-

    domain, multi-vendor, and multi-technology. An example of such

    centralized architecture is Abstraction and Control of Traffic

    Engineered Networks (ACTN) controller hierarchy described in RFC

    8453.



NEW:



    The advancement of software-defined transport networking technology

    enables a group of network elements to be managed through centralized

    controller hierarchies. This helps to tackle challenges arising from

    multiple domains, vendors, and technologies. An example of such a

    centralized architecture is the Abstraction and Control of Traffic

    Engineered Networks (ACTN) controller hierarchy, as described in RFC

    8453.



Abstract, paragraph 6:

OLD:



    Instead of competing with each other, both the distributed and the

    centralized control plane have their own advantages, and should be

    complementary in the system. This document describes how the GMPLS

    distributed control plane can interwork with a centralized

    controller system in a transport network.



NEW:



    Both the distributed and centralized control planes have their

    respective advantages and should complement each other in the system,

    rather than competing. This document outlines how the GMPLS

    distributed control plane can work together with a centralized

    controller system in a transport network.



Section 1., paragraph 3:

OLD:



    GMPLS can be applied for the Network Element (NE) level control in

    such centralized controller architectures. A centralized controller

    may support GMPLS enabled domains and interact with a GMPLS enabled

    domain where the GMPLS control plane does the service provisioning

    from ingress to egress. In this case the centralized controller

    sends the request to the ingress node and does not have to configure

    all NEs along the path through the domain from ingress to egress,

    thus leveraging the GMPLS control plane. This document describes how

    the GMPLS control plane interworks with a centralized controller

    system in a transport network.



NEW:



    GMPLS can be used to control Network Elements (NE) in such

    centralized controller architectures. A centralized controller may

    support GMPLS-enabled domains and communicate with a GMPLS-enabled

    domain where the GMPLS control plane handles service provisioning

    from ingress to egress. In this scenario, the centralized controller

    sends a request to the entry node and does not need to configure all

    NEs along the path within the domain from ingress to egress, thus

    leveraging the GMPLS control plane. This document describes how the

    GMPLS control plane interworks with a centralized controller system

    in a transport network.



Section 2., paragraph 1:

OLD:



    This section provides an overview of the GMPLS control plane and

    centralized controller systems and the interactions between the

    GMPLS control plane and centralized controllers, for transport

    networks.



NEW:



    This section presents an overview of the GMPLS control plane, centralized

    controller systems, and their interactions in transport networks.

[Author] OK, and now it’s in Section 3.





Section 2., paragraph 2:

OLD:



    A transport network [RFC5654] is a server-layer network designed to

    provide connectivity services for client-layer connectivity. This

    facilitates client traffic to be carried transparently across the

    server-layer network resources.



NEW:



   A transport network [RFC5654] is a server-layer network designed to

    provide connectivity services for client-layer connectivity. This

    setup allows client traffic to be carried seamlessly across

    server-layer network resources.

[Author] OK, and now it’s in Section 3.





Section 5.3., paragraph 1:

OLD:



    The PCE has been introduced in [RFC4655] as a functional component

    that provides services to compute paths in a network. In [RFC5440],

    the path computation is accomplished by using the TED, which

    maintains a view of the link resources in the network. The emergence

    of PCE efficiently improves the quality of network planning and

    offline computation. However, there is a risk that the computed path

    may be infeasible if there is a diversity requirement, because

    stateless PCE has no knowledge about the former computed paths.



NEW:



    The PCE was first introduced in [RFC4655] as a functional component

    that offers services for computing paths within a network. In

    [RFC5440], path computation is achieved using the TED, which

    maintains a view of the link resources in the network. The

    introduction of PCE has significantly improved the quality of network

    planning and offline computation. However, there is a potential risk

    that the computed path may be infeasible when there is a diversity

    requirement, as stateless PCE lacks knowledge about previously

    computed paths.

[Author] OK, and now it’s in Section 6.3.





Section 5.3., paragraph 4:

OLD:



    In a centralized controller system, the PCE can be implemented in a

    centralized controller, and the centralized controller performs path

    computation according to its local policies. On the other hand, the

    PCE can also be placed outside of the centralized controller. In

    this case, the centralized controller acts as a PCC to request path

    computation to the PCE through PCEP. One of the reference

    architecture can be found in [RFC7491].



NEW:



    In a centralized controller system, the PCE can be implemented within

    the centralized controller. The centralized controller then

    calculates paths based on its local policies. Alternatively, the PCE

    can be located outside of the centralized controller. In this

    scenario, the centralized controller functions as a PCC and sends a

    path computation request to the PCE using the PCEP. A reference

    architecture for this can be found in [RFC7491].

[Author] OK, and now it’s in Section 6.3.



Section 7.5., paragraph 1:

OLD:



    Given the important role in the network, the reliability of

    controller is critical. If the controller is shut down or

    disconnected from the network, it is highly desirable that all of

    the services currently provisioned in the network continue to

    function and carry traffic. Furthermore, protection switching to

    pre-established paths should also function. Additionally, it is

    desirable to provide protection mechanisms, such as redundancy, so

    that full operational control can be maintained even when one

    instance of the controller fails. This can be either achieved by

    controller back up or functionality back up. There are several of

    controller backup or federation mechanisms in the literature. It is

    also more reliable to have some function back up in the network

    element, to guarantee the performance in the network.



NEW:



    The reliability of the controller is crucial due to its important

    role in the network. It is essential that if the controller is shut

    down or disconnected from the network, all currently provisioned

    services in the network continue to function and carry traffic. In

    addition, protection switching to pre-established paths should also

    work. It is desirable to have protection mechanisms, such as

    redundancy, to maintain full operational control even if one instance

    of the controller fails. This can be achieved through controller

    backup or functionality backup. There are several controller backup

    or federation mechanisms in the literature. It is also more reliable

    to have function backup in the network element to guarantee

    performance in the network.

[Author] OK, and now it’s in Section 8.5.