Re: 6lowpan over wire, specifically over powerline?

Carsten Bormann <cabo@tzi.org> Mon, 28 March 2016 13:26 UTC

Return-Path: <cabo@tzi.org>
X-Original-To: ietf@ietfa.amsl.com
Delivered-To: ietf@ietfa.amsl.com
Received: from localhost (localhost [127.0.0.1]) by ietfa.amsl.com (Postfix) with ESMTP id B6E7412D916 for <ietf@ietfa.amsl.com>; Mon, 28 Mar 2016 06:26:13 -0700 (PDT)
X-Virus-Scanned: amavisd-new at amsl.com
X-Spam-Flag: NO
X-Spam-Score: -2.6
X-Spam-Level:
X-Spam-Status: No, score=-2.6 tagged_above=-999 required=5 tests=[BAYES_00=-1.9, RCVD_IN_DNSWL_LOW=-0.7] autolearn=ham autolearn_force=no
Received: from mail.ietf.org ([4.31.198.44]) by localhost (ietfa.amsl.com [127.0.0.1]) (amavisd-new, port 10024) with ESMTP id DQ1BnIm4SZoG for <ietf@ietfa.amsl.com>; Mon, 28 Mar 2016 06:26:12 -0700 (PDT)
Received: from relay6-d.mail.gandi.net (relay6-d.mail.gandi.net [IPv6:2001:4b98:c:538::198]) (using TLSv1.2 with cipher AECDH-AES256-SHA (256/256 bits)) (No client certificate requested) by ietfa.amsl.com (Postfix) with ESMTPS id 009BB12D91B for <ietf@ietf.org>; Mon, 28 Mar 2016 06:26:07 -0700 (PDT)
Received: from mfilter43-d.gandi.net (mfilter43-d.gandi.net [217.70.178.174]) by relay6-d.mail.gandi.net (Postfix) with ESMTP id 7CD44FB877; Mon, 28 Mar 2016 15:26:05 +0200 (CEST)
X-Virus-Scanned: Debian amavisd-new at mfilter43-d.gandi.net
Received: from relay6-d.mail.gandi.net ([IPv6:::ffff:217.70.183.198]) by mfilter43-d.gandi.net (mfilter43-d.gandi.net [::ffff:10.0.15.180]) (amavisd-new, port 10024) with ESMTP id kMscI-FrLVJz; Mon, 28 Mar 2016 15:26:03 +0200 (CEST)
X-Originating-IP: 93.199.229.85
Received: from nar.local (p5DC7E555.dip0.t-ipconnect.de [93.199.229.85]) (Authenticated sender: cabo@cabo.im) by relay6-d.mail.gandi.net (Postfix) with ESMTPSA id A47B8FB8AC; Mon, 28 Mar 2016 15:26:02 +0200 (CEST)
Message-ID: <56F930E8.8050108@tzi.org>
Date: Mon, 28 Mar 2016 15:26:00 +0200
From: Carsten Bormann <cabo@tzi.org>
User-Agent: Postbox 4.0.8 (Macintosh/20151105)
MIME-Version: 1.0
To: Patrik Fältström <paf@frobbit.se>
Subject: Re: 6lowpan over wire, specifically over powerline?
References: <852C9AF7-A5C5-4F49-B2DE-A997F4DB576E@frobbit.se>
In-Reply-To: <852C9AF7-A5C5-4F49-B2DE-A997F4DB576E@frobbit.se>
X-Enigmail-Version: 1.2.3
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: 8bit
Archived-At: <http://mailarchive.ietf.org/arch/msg/ietf/XHULFZ8RtKz4ef0f7K9KPk_JxsE>
Cc: IETF discussion list <ietf@ietf.org>
X-BeenThere: ietf@ietf.org
X-Mailman-Version: 2.1.17
Precedence: list
List-Id: IETF-Discussion <ietf.ietf.org>
List-Unsubscribe: <https://www.ietf.org/mailman/options/ietf>, <mailto:ietf-request@ietf.org?subject=unsubscribe>
List-Archive: <https://mailarchive.ietf.org/arch/browse/ietf/>
List-Post: <mailto:ietf@ietf.org>
List-Help: <mailto:ietf-request@ietf.org?subject=help>
List-Subscribe: <https://www.ietf.org/mailman/listinfo/ietf>, <mailto:ietf-request@ietf.org?subject=subscribe>
X-List-Received-Date: Mon, 28 Mar 2016 13:26:13 -0000

Patrik Fältström wrote:
> Hi,
> 
> This is a shot in the dark, but has anyone been looking at implementing things like 6lowpan on wire protocols, 

Yes.

https://tools.ietf.org/html/draft-ietf-6lo-6lobac

> specifically over power lines? 

Which PLC spec specifically are you thinking about?

Grüße, Carsten