[tsvwg] Technical discussion 3 of draft-ietf-tsvwg-aqm-dualq-coupled-08

David Pullen <david.pullen@broadcom.com> Mon, 17 December 2018 15:55 UTC

Return-Path: <david.pullen@broadcom.com>
X-Original-To: tsvwg@ietfa.amsl.com
Delivered-To: tsvwg@ietfa.amsl.com
Received: from localhost (localhost [127.0.0.1]) by ietfa.amsl.com (Postfix) with ESMTP id B120D128CF3 for <tsvwg@ietfa.amsl.com>; Mon, 17 Dec 2018 07:55:53 -0800 (PST)
X-Virus-Scanned: amavisd-new at amsl.com
X-Spam-Flag: NO
X-Spam-Score: -3.46
X-Spam-Level:
X-Spam-Status: No, score=-3.46 tagged_above=-999 required=5 tests=[BAYES_00=-1.9, DKIMWL_WL_HIGH=-1.46, DKIM_SIGNED=0.1, DKIM_VALID=-0.1, DKIM_VALID_AU=-0.1, HTML_MESSAGE=0.001, RCVD_IN_DNSWL_NONE=-0.0001, SPF_PASS=-0.001] autolearn=ham autolearn_force=no
Authentication-Results: ietfa.amsl.com (amavisd-new); dkim=pass (1024-bit key) header.d=broadcom.com
Received: from mail.ietf.org ([4.31.198.44]) by localhost (ietfa.amsl.com [127.0.0.1]) (amavisd-new, port 10024) with ESMTP id AbskEidwY33S for <tsvwg@ietfa.amsl.com>; Mon, 17 Dec 2018 07:55:50 -0800 (PST)
Received: from mail-qk1-x72c.google.com (mail-qk1-x72c.google.com [IPv6:2607:f8b0:4864:20::72c]) (using TLSv1.2 with cipher ECDHE-RSA-AES128-GCM-SHA256 (128/128 bits)) (No client certificate requested) by ietfa.amsl.com (Postfix) with ESMTPS id 9FBCD130E61 for <tsvwg@ietf.org>; Mon, 17 Dec 2018 07:55:50 -0800 (PST)
Received: by mail-qk1-x72c.google.com with SMTP id 189so7579049qkj.8 for <tsvwg@ietf.org>; Mon, 17 Dec 2018 07:55:50 -0800 (PST)
DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=broadcom.com; s=google; h=mime-version:from:date:message-id:subject:to:cc; bh=Et4jFDCGm6rY4mrw2PRfT2swjEXc5YNvevJm8uOKzgM=; b=D3AQt5LAbZ1B2qrdWiWgecTr3TfL3xwF4IWm3YLQiM/8QKFWaqcGIwoaTOVqTpxCbm VIW7zna7p2mRAAyD242fl7ubhhvmvD+RZgX7Z94fe7wMrII/MW9W9f7LVN+p9nociT+0 kvKisLZaqVyY+/U/hwlgHU3veCtjhMPYbb3cc=
X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20161025; h=x-gm-message-state:mime-version:from:date:message-id:subject:to:cc; bh=Et4jFDCGm6rY4mrw2PRfT2swjEXc5YNvevJm8uOKzgM=; b=Xh+eApxdo2IlR2ldzuifjmbr5WkKjjcCCwIZ1+P2hAv6+pht63G/oRcn86EaY0krI0 DHEv9j/QMSJCC3CuSN56yA73IdbEGjSESnn5W+8g+mWAg9P54/SeL1uRdAaqVAMLize7 5EGvQFPuikn2183f+mE/s2uGMIWaoesJg+3s/ik2u7Du3GDFcEJnM1zDnOPQWmpgRlyu JRgLJANSTG3+sAYwVq4hZxIIFrxUulS9XWPcO8Ts0RamMQlRbCLr1Ddk0BG0kf1bW9J3 Tiz9YgDgbSUTM3NKbPVVF2PfD3vhvH3ARmWYW8zoQ5fJtyxOSontP9E9Nza0+Sm15DV5 JiBg==
X-Gm-Message-State: AA+aEWZmtrOgVjHrN487piElP50DM7/UwCh5wotRDOhBDnLzT3o2akjI T7J9WRdfnATN4eiv1ySoMKENgXprbDfuXzUDyNqGvx6tjDI=
X-Google-Smtp-Source: AFSGD/VJL40p2DCqGAMpxG8NRqY4iSpnYVRHGX2VFtp1tbFYOGhoPIEJG232yN2/llLk/ByBilSwRQYLprf1vqtYfqU=
X-Received: by 2002:a37:2881:: with SMTP id o1mr12873005qko.130.1545062149709; Mon, 17 Dec 2018 07:55:49 -0800 (PST)
MIME-Version: 1.0
From: David Pullen <david.pullen@broadcom.com>
Date: Mon, 17 Dec 2018 10:55:58 -0500
Message-ID: <CAA+foQUsOGeSpqqJw6OSJxJOg8p9fZ_L9fVvP1HThSBsiuGNYw@mail.gmail.com>
To: ietf@bobbriscoe.net
Cc: tsvwg@ietf.org
Content-Type: multipart/alternative; boundary="000000000000971b3b057d39d01e"
Archived-At: <https://mailarchive.ietf.org/arch/msg/tsvwg/beQwnL8_oR8jrQ1YwmXkKMbSUUw>
Subject: [tsvwg] Technical discussion 3 of draft-ietf-tsvwg-aqm-dualq-coupled-08
X-BeenThere: tsvwg@ietf.org
X-Mailman-Version: 2.1.29
Precedence: list
List-Id: Transport Area Working Group <tsvwg.ietf.org>
List-Unsubscribe: <https://www.ietf.org/mailman/options/tsvwg>, <mailto:tsvwg-request@ietf.org?subject=unsubscribe>
List-Archive: <https://mailarchive.ietf.org/arch/browse/tsvwg/>
List-Post: <mailto:tsvwg@ietf.org>
List-Help: <mailto:tsvwg-request@ietf.org?subject=help>
List-Subscribe: <https://www.ietf.org/mailman/listinfo/tsvwg>, <mailto:tsvwg-request@ietf.org?subject=subscribe>
X-List-Received-Date: Mon, 17 Dec 2018 15:55:54 -0000

Hi Bob,

In section 2.5.1.1, there is a bullet list that describes the expected
behavior for different conditions (ECT(0), ECT(1), not-ECT), but doesn't
describe what to do if the codepoint is CE.

This topic probably should have been combined with technical discussion 2,
since it is related...

Thanks,
  - Dave

David Pullen
Distinguished Engineer  |  Wired Networking, Cable Modems
Broadcom

office: 678.475.3143  |  mobile: 678.477.4108  |  fax: 770.232.0211
4385 River Green Parkway  |  Duluth, GA 30096
david.pullen@broadcom.com   |   broadcom.com